Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Eur J Cancer ; 199: 113553, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38262307

RESUMO

AIM: The analyses here reported aim to compare the screening performance of digital tomosynthesis (DBT) versus mammography (DM). METHODS: MAITA is a consortium of four Italian trials, REtomo, Proteus, Impeto, and MAITA trial. The trials adopted a two-arm randomised design comparing DBT plus DM (REtomo and Proteus) or synthetic-2D (Impeto and MAITA trial) versus DM; multiple vendors were included. Women aged 45 to 69 years were individually randomised to one round of DBT or DM. FINDINGS: From March 2014 to February 2022, 50,856 and 63,295 women were randomised to the DBT and DM arm, respectively. In the DBT arm, 6656 women were screened with DBT plus synthetic-2D. Recall was higher in the DBT arm (5·84% versus 4·96%), with differences between centres. With DBT, 0·8/1000 (95% CI 0·3 to 1·3) more women received surgical treatment for a benign lesion. The detection rate was 51% higher with DBT, ie. 2·6/1000 (95% CI 1·7 to 3·6) more cancers detected, with a similar relative increase for invasive cancers and ductal carcinoma in situ. The results were similar below and over the age of 50, at first and subsequent rounds, and with DBT plus DM and DBT plus synthetic-2D. No learning curve was appreciable. Detection of cancers >= 20 mm, with 2 or more positive lymph nodes, grade III, HER2-positive, or triple-negative was similar in the two arms. INTERPRETATION: Results from MAITA confirm that DBT is superior to DM for the detection of cancers, with a possible increase in recall rate. DBT performance in screening should be assessed locally while waiting for long-term follow-up results on the impact of advanced cancer incidence.


Assuntos
Neoplasias da Mama , Carcinoma Intraductal não Infiltrante , Feminino , Humanos , Mama/diagnóstico por imagem , Mama/patologia , Neoplasias da Mama/diagnóstico , Detecção Precoce de Câncer/métodos , Incidência , Mamografia/métodos , Programas de Rastreamento/métodos , Pessoa de Meia-Idade , Idoso , Ensaios Clínicos Controlados Aleatórios como Assunto
2.
Radiology ; 303(2): 256-266, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35103537

RESUMO

Background Adding digital breast tomosynthesis (DBT) to digital mammography (DM) improves breast cancer screening sensitivity, but how this impacts mortality and other end points is unknown. Purpose To compare interval and overall breast cancer incidence after screening with DBT plus DM versus DM alone. Materials and Methods In this prospective trial (RETomo), women attending screening were randomized to one round of DBT plus DM (experimental arm) or to DM (control arm). All were then rescreened with DM after 12 months (women aged 45-49 years) or after 24 months (50-69 years). The primary outcome was interval cancer incidence. Cumulative incidence up to the subsequent screening round plus 9 months (21- and 33-month follow-up for women aged 45-49 and 50-69, respectively) was also reported. Ductal carcinomas in situ are included. Subgroup analyses by age and breast density were conducted; 95% CIs computed according to binomial distribution are reported. Results Baseline cancer detection was higher in the DBT plu DM arm than DM arm (101 of 13 356 women vs 61 of 13 521 women; relative detection, 1.7 [95% CI: 1.2, 2.3]). The mean age ± standard deviation for the women in both arms was 55 years ± 7. Interval cancer incidence was similar in the two arms (21 vs 22 cancers; relative incidence, 0.97 [95% CI: 0.53, 1.8]). Cumulative incidence remained higher in the DBT plus DM arm in women over 50 (153 vs 124 cancers; relative incidence, 1.2 [95% CI: 0.99, 1.6]), while it was similar in the two arms in women aged 45-49 (36 vs 41 cancers; relative incidence, 0.89 [95% CI: 0.57, 1.4]). Conclusion In women younger than 50 years, the benefit of early diagnosis seemed to be appreciable, while for women over age 50, the higher sensitivity of tomosynthesis plus mammography was not matched by a subsequent reduction in cancers at the next screening examination or in the intervening interval. Clinical trial registration no. NCT02698202 © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Lee and Ray in this issue.


Assuntos
Neoplasias da Mama , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/epidemiologia , Neoplasias da Mama/patologia , Feminino , Humanos , Incidência , Masculino , Mamografia/métodos , Estudos Prospectivos , Sensibilidade e Especificidade
3.
Fetal Pediatr Pathol ; 41(2): 281-292, 2022 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-32538685

RESUMO

Background Apert syndrome is characterized by craniosynostosis, midface hypoplasia and symmetric syndactyly. Case report: A 36-year-old mother, G2P1 underwent an ultrasound scan at 19 week's gestation. There was craniosynostosis, brachi-turricephaly and bilateral hand syndactyly. Genomic DNA from amniocentesis revealed the mutation C758C>Gp. (Pro to Arg substitution) at 252 of the exon 8 of the FGFR2 encoding for Apert syndrome. The pregnancy was terminated. Femoral chondral plate histology showed an increased interstitial matrix between bony trabeculae. Compared with normal, the trabeculae were thinner, more irregular with numerous osteoclasts suggesting abnormal bone remodeling. Hands and feet had an abrupt transition between resting and proliferating cartilage. Conclusion: Apert syndrome has increased intertrabecular matrix, thin trabeculae, increased remodeling, and irregular transition between the maturing and mineralization zones in the femur, and abnormal abrupt transition between the resting and proliferating cartilage in the fingers and toes.


Assuntos
Acrocefalossindactilia , Acrocefalossindactilia/diagnóstico por imagem , Acrocefalossindactilia/genética , Adulto , Feminino , Humanos , Mutação , Gravidez , Tomografia Computadorizada por Raios X , Ultrassonografia Pré-Natal
4.
Radiology ; 288(2): 375-385, 2018 08.
Artigo em Inglês | MEDLINE | ID: mdl-29869961

RESUMO

Purpose To compare digital mammography (DM) plus digital breast tomosynthesis (DBT) versus DM alone for breast cancer screening in the Reggio Emilia Tomosynthesis trial, a two-arm test-and-treat randomized controlled trial. Materials and Methods For this trial, eligible women (45-70 years old) who previously participated in the Reggio Emilia screening program were invited for mammography. Consenting women were randomly assigned 1:1 to undergo DBT+DM or DM (both of which involved two projections and double reading). Women were treated according to the decision at DBT+DM. Sensitivity, recall rate, and positive predictive value (PPV) at baseline were determined; the ratios of these rates for DBT+DM relative to DM alone were determined. Results From March 2014 to March 2016, 9777 women were recruited to the DM+DBT arm of the study, and 9783 women were recruited to the DM arm (mean age, 56.2 vs 56.3 years). Recall was 3.5% in both arms; detection was 4.5 per 1000 (44 of 9783) and 8.6 per 1000 (83 of 9777), respectively (+89%; 95% confidence interval [CI]: 31, 72). PPV of the recall was 13.0% and 24.1%, respectively (P = .0002); 72 of 80 cancers found in the DBT+DM arm and with complete DBT imaging were positive at least at one DBT-alone reading. The greater detection rate for DM+DBT was stronger for ductal carcinoma in situ (+180%, 95% CI: 1, 665); it was notable for small and medium invasive cancers, but not for large ones (+94 [95% CI: 6, 254]; +122 [95% CI: 18, 316]; -12 [95% CI: -68, 141]; for invasive cancers < 10 mm, 10-19 mm, and ≥ 20 mm, respectively). Conclusion DBT+DM depicts 90% more cancers in a population previously screened with DM, with similar recall rates.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Mamografia/métodos , Programas de Rastreamento/métodos , Intensificação de Imagem Radiográfica/métodos , Idoso , Mama/diagnóstico por imagem , Feminino , Humanos , Itália , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
5.
Breast Cancer Res ; 19(1): 106, 2017 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-28893303

RESUMO

BACKGROUND: Neoadjuvant-chemotherapy (NAC) is considered the standard treatment for locally advanced breast carcinomas. Accurate assessment of disease response is fundamental to increase the chances of successful breast-conserving surgery and to avoid local recurrence. The purpose of this study was to compare contrast-enhanced spectral mammography (CESM) and contrast-enhanced-MRI (MRI) in the evaluation of tumor response to NAC. METHODS: This prospective study was approved by the institutional review board and written informed consent was obtained. Fifty-four consenting women with breast cancer and indication of NAC were consecutively enrolled between October 2012 and December 2014. Patients underwent both CESM and MRI before, during and after NAC. MRI was performed first, followed by CESM within 3 days. Response to therapy was evaluated for each patient, comparing the size of the residual lesion measured on CESM and MRI performed after NAC to the pathological response on surgical specimens (gold standard), independently of and blinded to the results of the other test. The agreement between measurements was evaluated using Lin's coefficient. The agreement between measurements using CESM and MRI was tested at each step of the study, before, during and after NAC. And last of all, the variation in the largest dimension of the tumor on CESM and MRI was assessed according to the parameters set in RECIST 1.1 criteria, focusing on pathological complete response (pCR). RESULTS: A total of 46 patients (85%) completed the study. CESM predicted pCR better than MRI (Lin's coefficient 0.81 and 0.59, respectively). Both methods tend to underestimate the real extent of residual tumor (mean 4.1mm in CESM, 7.5mm in MRI). The agreement between measurements using CESM and MRI was 0.96, 0.94 and 0.76 before, during and after NAC respectively. The distinction between responders and non-responders with CESM and MRI was identical for 45/46 patients. In the assessment of CR, sensitivity and specificity were 100% and 84%, respectively, for CESM, and 87% and 60% for MRI. CONCLUSION: CESM and MRI lesion size measurements were highly correlated. CESM seems at least as reliable as MRI in assessing the response to NAC, and may be an alternative if MRI is contraindicated or its availability is limited.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/tratamento farmacológico , Mama/diagnóstico por imagem , Terapia Neoadjuvante , Adulto , Idoso , Mama/efeitos dos fármacos , Mama/patologia , Neoplasias da Mama/patologia , Meios de Contraste/uso terapêutico , Feminino , Humanos , Imageamento por Ressonância Magnética/métodos , Mamografia/métodos , Pessoa de Meia-Idade , Recidiva Local de Neoplasia/diagnóstico por imagem , Recidiva Local de Neoplasia/tratamento farmacológico , Recidiva Local de Neoplasia/patologia , Estudos Prospectivos , Resultado do Tratamento
6.
Congenit Anom (Kyoto) ; 54(4): 228-32, 2014 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-24517215

RESUMO

Prenatal diagnosis of thanatophoric dysplasia (TD) type II presenting in the first trimester with increased nuchal translucency (NT) and cloverleaf skull (Kleeblattschaedel) have been scantly reported in the medical record. Abnormal choroid plexus has been seen in association with fetal anomalies. Here we described a case of increased NT associated with indented choroid plexuses, early onset hydrocephalus and cloverleaf skull in a fetus subsequently diagnosed at early second trimester to carry a de novo mutation encoding for TD type II. The findings of dysmorphic choroid plexus, early onset hydrocephalus and cloverleaf skull at first trimester scan may be early, useful ultrasound markers of TD type II. Molecular analysis to control for possible overlapping syndromes were performed and resulted negative. Postmortem X-ray and 3D-CT scan confirmed the cloverleaf skull, narrow thorax, straight femur with rhizomelic shortening of the limbs and the presence of a communicating hydrocephalus.


Assuntos
Plexo Corióideo/diagnóstico por imagem , Craniossinostoses/diagnóstico por imagem , Hidrocefalia/diagnóstico por imagem , Crânio/anormalidades , Displasia Tanatofórica/diagnóstico por imagem , Adulto , Plexo Corióideo/patologia , Craniossinostoses/complicações , Craniossinostoses/patologia , Feminino , Feto , Humanos , Hidrocefalia/complicações , Hidrocefalia/patologia , Medição da Translucência Nucal , Gravidez , Primeiro Trimestre da Gravidez , Diagnóstico Pré-Natal , Crânio/diagnóstico por imagem , Crânio/patologia , Displasia Tanatofórica/complicações , Displasia Tanatofórica/patologia , Ultrassonografia Pré-Natal
7.
J Digit Imaging ; 26(3): 412-8, 2013 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-23224607

RESUMO

In RIS-PACS systems, potential errors occurring during the execution of a radiologic examination can amplify the clinical risks of the patient during subsequent treatments, e.g., of oncologic patients or of those who must do additional treatments based on the initial diagnosis. In Reggio Emilia Province Diagnostic Imaging Department (REDID) we experienced different strategies to reduce clinical risks due to patient reconciliation errors. In 2010, we developed a procedure directly integrated in our RIS-PACS that uses Health Level 7 (HL7) standard messaging, which generates an overlay with the text "under investigation" on the images of the study to be corrected. All the healthcare staff is informed of the meaning of that overlay, and only the radiologist and the emergency services staff can consult these images on PACS. The elimination of image overlay and of any access limitation to PACS was triggered to confirm of the right correction made by RIS-PACS system administrator (SA). The RIS-PACS integrated tool described in this paper allows technologists and radiologists to efficiently highlight patient exam errors and to inform all the users to minimize the overall clinical risks, with a significant savings in costs. Over the years, we have observed a steady decrease in the percentage of reconciled studies. Error reconciliation requires an effective and efficient mechanism. The RIS-PACS integrated tool described in this paper enables technologists and radiologists to quickly and efficiently highlight patient exam errors and inform all the users. Next generation of RIS-PACS could be equipped with similar reconciliation tools.


Assuntos
Erros de Diagnóstico/prevenção & controle , Nível Sete de Saúde , Garantia da Qualidade dos Cuidados de Saúde , Sistemas de Informação em Radiologia/organização & administração , Difusão de Inovações , Eficiência Organizacional , Humanos , Risco
8.
Med Phys ; 39(5): 2617-27, 2012 May.
Artigo em Inglês | MEDLINE | ID: mdl-22559632

RESUMO

PURPOSE: The purpose of this study is to compare digital radiography systems using the metric effective detective quantum efficiency (eDQE), which better reflects digital radiography imaging system performance under clinical operating conditions, in comparison with conventional metrics such as modulation transfer function (MTF), normalized noise power spectra (NNPS), and detective quantum efficiency (DQE). METHODS: The eDQE was computed by the calculation of the MTF, the NNPS, the phantom attenuation and scatter, and estimation of x-ray flux. The physical characterization of the systems was obtained with the standard beam conditions RQA5 and RQA9, using the PA Chest phantom proposed by AAPM Report # 31 simulating the attenuation and scatter characteristics of the adult human thorax. The MTF (eMTF) was measured by using an edge test placed at the frontal surface of the phantom, the NNPS (eNNPS) was calculated from images of the phantom acquired at three different exposure levels covering the operating range of the system (E(0), which is the exposure at which a system is normally operated, 1/3 E(0), and 3 E0), and scatter measurements were assessed by using a beam-stop technique. The integral of DQE (IDQE) and eDQE (IeDQE) was calculated over the whole spatial frequency range. RESULTS: The eMTF results demonstrate degradation due to magnification and the presence of scattered radiation. The eNNPS was influenced by the grid presence, and in some systems, it contained structured noise. At typical clinical exposure levels, the magnitude of eDQE(0) with respect to DQE(0) at RQA9 beam conditions was 13%, 17%, 16%, 36%, and 24%, respectively, for Carestream DRX-1, Carestream DRX-1C, Carestream Direct View CR975, Philips Digital Diagnost VM, and GE Revolution XR/d. These results were confirmed by the ratio of IeDQE and IDQE in the same conditions. CONCLUSIONS: The authors confirm the robustness and reproducibility of the eDQE method. As expected, the DR systems performed better than the CR systems due to their superior signal-to-noise transfer characteristics. The results of this study suggest the eDQE method may provide an opportunity to more accurately assess the clinical performance of digital radiographic imaging systems by accounting for factors such as the presence of scatter, use of an antiscatter grid, and magnification and focal spot blurring effects, which are not reflected in conventional DQE measures.


Assuntos
Intensificação de Imagem Radiográfica/métodos , Adulto , Césio , Gadolínio , Hospitais , Humanos , Iodetos , Medições Luminescentes , Imagens de Fantasmas , Radiografia Torácica , Espalhamento de Radiação
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...